Rated working voltage Un(DC) |
210V |
420V |
890V |
Maximum continuous working voltage Uc(DC) |
250V |
500V |
1000V |
Nominal discharge current (8/20μs) ln (kA) |
20 |
||
Maximum discharge current (8/20μs)lmax(kA) |
40 |
||
Voltage protection level Up(kV) |
2 |
2.6 |
3.6 |
Continuous working current Ucpv |
<0.1mA |
||
Residual Ucpv |
<0.1mA |
||
Rated short-circuit current Iscpv(kA) |
15 |
||
thermal trip device |
built-in |
||
Response time I (ns) |
<25 |
||
Test classification |
Class II |
||
degree of protection |
IP20 |
||
Environmental limit temperature |
- 35 °C~+ 70 °C |
||
Installation type |
35MM electrical rail |
||
Shell material |
Thermoplastic material, complies with UL94-V0 |
||
shell color |
White |
||
Normal/fault display |
green red |
||
Recommended fuse or circuit breaker (A) |
16~25 |
||
It is recommended to connect the phase line and neutral line diameter (mm²) |
4~16 |
||
Ground PE |
4~16A |
DC250V/500V/1000V optional
Recommended wiring 4~16mm2, maximum support 25mm2 wiring
When the module indicator is red, it means that the module has suffered a lightning strike, the module can no longer protect the line, and needs to be replaced in time
Unique arc isolation design and adding an arc isolation sheet, it can effectively isolate the risk of short circuit caused by arc discharge under high voltage state (1000V).
Shell: thermoplastic material, in line with UL94-V0, flame retardant and corrosion resistant
Internal components: nickel-plated copper conductor, high-voltage-resistant film-coated chip, waterproof and anti-corrosion
Provide 12-month quality assurance, except for man-made, normal lightning strikes, wrong wiring damage, free replacement
1
1
1. What does a surge protector do
Its main function is to control the instantaneous overcurrent and voltage that suddenly enter the wire loop and signal transmission line within the range that the equipment can withstand, or introduce a strong lightning strike current into the ground to ensure that the equipment or system can be safe and stable. The work will not be damaged by impact.
2. One line or several days of lines need to install several surge protectors.
Usually, one is installed for the main line and one for the terminal line, and it is necessary to add one for special places.
3. delivery time
Under normal circumstances, the delivery time will not exceed 3 days. In special cases, such as have no enough stocks, the delivery will be delayed, and the longest delivery time will not exceed 7 days.
4. About shipping time
Due to the geographical location and transportation environment of different countries, the delivery time of goods in different countries is different. For example, Southeast Asian countries usually take 10-15 days, most European countries and the United States 15-25 days, etc., and remote countries may exceed 30 days. Please waiting patiently.